Laser Scan Micrometer LSM-902/6900 – Series 544

Compare

$12,395.00

‘- Non-contact laser-based measuring system, mainly for outside diameter measurement.Suitable for delicate or moving workpieces.
– Accuracy of ±0.5?m in the ø0.1 – ø25mm range can be achieved. It is highly suitable suited for pin gage measurement.
– Narrow range accuracy of ±(0.3+0.1 D)?m for high precision measurement.
– Ultra-high repeatability of ±0.05?m.
– The system consists of a measuring unit (LSM-902) and a display unit (LSM-6900).

Clear
SKU: N/A Category:
SKURangeMeasuring Region AreaRepeatabilityNo. of ScansLaser Scanning SpeedLinearity (whole range)Linearity (small range)Reading RangePositional ErrorPriceBuyhf:att:pa_10-pin-digimatic-inputhf:att:pa_2d-viewhf:att:pa_a-axis-indexinghf:att:pa_ac-adapterhf:att:pa_academic-licensehf:att:pa_angle-directionhf:att:pa_applicable-gagehf:att:pa_archive-datahf:att:pa_assignable-cause-actionhf:att:pa_attribute-msa-4hf:att:pa_attribute-short-methodhf:att:pa_audit-trailshf:att:pa_auto-generated-emailshf:att:pa_automates-reportinghf:att:pa_b-axis-indexinghf:att:pa_batch-data-collectionhf:att:pa_batteryhf:att:pa_battery-lifehf:att:pa_bias-studyhf:att:pa_bluetooth-4-2hf:att:pa_bracket-kithf:att:pa_cable-lengthhf:att:pa_cable-namehf:att:pa_cable-typehf:att:pa_classic-spc-viewshf:att:pa_cloud-environmenthf:att:pa_collection-schedulerhf:att:pa_colorhf:att:pa_column-row-mappinghf:att:pa_connectionhf:att:pa_connection-cable-requiredhf:att:pa_connection-typehf:att:pa_connection-unit-requiredhf:att:pa_continuous-data-sendhf:att:pa_custom-calibration-certhf:att:pa_custom-calibration-prochf:att:pa_custom-report-templateshf:att:pa_d2hf:att:pa_data-entryhf:att:pa_data-inputhf:att:pa_data-outputhf:att:pa_data-processing-0hf:att:pa_data-processing-1hf:att:pa_data-processing-3hf:att:pa_data-reception-indicationhf:att:pa_data-send-buttonhf:att:pa_data-send-switchhf:att:pa_data-storagehf:att:pa_datasheethf:att:pa_depth-of-fieldhf:att:pa_displayhf:att:pa_editionhf:att:pa_electronic-signatureshf:att:pa_email-alertshf:att:pa_external-controlhf:att:pa_factory-quality-dashboardhf:att:pa_filterhf:att:pa_fithf:att:pa_fit-transmitterhf:att:pa_footswitch-connectionhf:att:pa_form-vision-connectivityhf:att:pa_free-mobile-appshf:att:pa_functionhf:att:pa_gage-capacityhf:att:pa_gage-managementhf:att:pa_gage-rrhf:att:pa_head-mountinghf:att:pa_hoops-3d-viewhf:att:pa_import-asciihf:att:pa_import-gage-libraryhf:att:pa_improves-work-efficiencyhf:att:pa_includes-sql-expresshf:att:pa_inputshf:att:pa_item-typehf:att:pa_lengthhf:att:pa_linearity-studyhf:att:pa_live-collection-dashboardhf:att:pa_manager-viewshf:att:pa_masshf:att:pa_max-min-tirhf:att:pa_maximum-extension-barhf:att:pa_measuring-toolshf:att:pa_merge-copy-and-edit-datahf:att:pa_modelhf:att:pa_mounting-optionshf:att:pa_network-connectedhf:att:pa_number-of-licenseshf:att:pa_operating-temperature-rangehf:att:pa_optional-vcp-drivershf:att:pa_outputhf:att:pa_outside-dimensionshf:att:pa_overtravel-break-loadhf:att:pa_pass-thru-port-inputhf:att:pa_pc-requirementhf:att:pa_polling-from-pchf:att:pa_positional-repeatabilityhf:att:pa_positionshf:att:pa_power-supplyhf:att:pa_print-capacityhf:att:pa_print-speedhf:att:pa_printer-paperhf:att:pa_printing-methodhf:att:pa_probe-mountinghf:att:pa_probe-socketshf:att:pa_probe-status-indicationhf:att:pa_process-analyzerhf:att:pa_process-managerhf:att:pa_range-x-axishf:att:pa_range-y-axishf:att:pa_real-time-professionalhf:att:pa_real-time-standardhf:att:pa_remarkshf:att:pa_repeatability-of-positionhf:att:pa_report-schedulerhf:att:pa_request-datahf:att:pa_resolutionhf:att:pa_rs-232c-cablehf:att:pa_rs232-outputhf:att:pa_scatter-charthf:att:pa_serial-rs232-inputhf:att:pa_signalhf:att:pa_spc-cablehf:att:pa_stability-studyhf:att:pa_suitable-interfaceshf:att:pa_summary-analysishf:att:pa_supplies-5vhf:att:pa_support-capabilityhf:att:pa_supported-oshf:att:pa_supports-mobile-deviceshf:att:pa_supports-u-wavehf:att:pa_supports-usb-input-toolhf:att:pa_supports-usb-itnhf:att:pa_tagging-datahf:att:pa_tech-support-includedhf:att:pa_test-for-normalityhf:att:pa_timed-data-collectionhf:att:pa_timed-data-sendhf:att:pa_timer-inputhf:att:pa_tolerance-judgementhf:att:pa_track-gage-calibrationhf:att:pa_transmitterhf:att:pa_type-1-studyhf:att:pa_u-wave-bluetoothhf:att:pa_u-wave-r-requiredhf:att:pa_u-wave-r-unitshf:att:pa_u-wave-thf:att:pa_u-wave-t-unitshf:att:pa_usb-cablehf:att:pa_usb-drivershf:att:pa_usb-outputhf:att:pa_variable-crossed-anovahf:att:pa_variable-crossed-rangehf:att:pa_variable-nested-anovahf:att:pa_variable-nested-rangehf:att:pa_variable-range-methodhf:att:pa_workgroup-site-licensehf:att:pa_workpiece-max-load
544-499-1A.004-1.0in 0.1-25mm.6in x 1.0in / 1.5x25mm.000002in 0.05 *2um800/sec2240in/sec(56m/sec)± .00002” (±0.5µm)*3± (.000012 + .0001 ?D)” [?D:inch]*3 *4 ±(0.3 + 0.1 ?D)µm [?D:mm]*3*40.00001-0.0005in 0.01-10um.000020in 0.5um$12,395.00

Optional Accessories

SKUDescriptionPriceBuy
937179TFOOT SWITCH$95.80
02AGD180CALIBRATION GAGE SET FOR LSM-902$1,050.00
02AGD270WORKSTAGE FOR LSM-501/503/902$914.00
02AGD280ADJUSTABLE WORKSTAGE FOR LSM-902$1,940.00
02AGC840DIGIMATIC CODEOUT UNIT$125.00
02AGC880I/O ANALOG INTERFACE UNIT$935.00
02AGC910BCD INTERFACE UNIT$665.00

Features

– Non-contact laser-based measuring system, mainly for outside diameter measurement.Suitable for delicate or moving workpieces.
– Accuracy of ±0.5?m in the ø0.1 – ø25mm range can be achieved. It is highly suitable suited for pin gage measurement.
– Narrow range accuracy of ±(0.3+0.1 D)?m for high precision measurement.
– Ultra-high repeatability of ±0.05?m.
– The system consists of a measuring unit (LSM-902) and a display unit (LSM-6900).

Optional Accessories

Calibration gage set (ø1.0, ø25.0): No.02AGD180
Workstage: No.02AGD270
Adjustable workstage: No.02AGD280
Digimatic code output unit (2-ch): No.02AGC840
2nd I/O analog interface unit: No.02AGC880
BCD interface unit: No.02AGC910
Printer & cable set (120V AC C-type plug): No.02AGD600B
Printing paper TP411-28CL / 1Pack = 10pcs: No.223663
Digimatic code output cable: No.936937
Foot switch: No.937179T

Additional information

Weight N/A
Dimensions N/A
Range

.004-1.0in 0.1-25mm

Measuring Region Area

.6in x 1.0in / 1.5x25mm

Repeatability

.000002in 0.05 *2um

No. of Scans

800/sec

Laser Scanning Speed

2240in/sec(56m/sec)

Linearity

± .00002” (±0.5µm)*3

Linearity (small range)

± (.000012 + .0001 ?D)” [?D:inch]*3 *4 ±(0.3 + 0.1 ?D)µm [?D:mm]*3*4

Reading Range

0.00001-0.0005in 0.01-10um

Positional Error

.000020in 0.5um

Reviews

There are no reviews yet.

Be the first to review “Laser Scan Micrometer LSM-902/6900 – Series 544”

Your email address will not be published.

Select the fields to be shown. Others will be hidden. Drag and drop to rearrange the order.
  • Image
  • SKU
  • Rating
  • Price
  • Stock
  • Availability
  • Add to cart
  • Description
  • Weight
  • Dimensions
  • Additional information
  • Attributes
  • Custom attributes
  • Custom fields
Click outside to hide the compare bar
Compare
Compare ×
Let's Compare! Continue shopping