SKU | Item Type | Model No. | Range | Accuracy | LCD Resolution | Price | Buy | hf:att:pa_item-type | hf:att:pa_10-pin-digimatic-input | hf:att:pa_2d-view | hf:att:pa_a-axis-indexing | hf:att:pa_ac-adapter | hf:att:pa_academic-license | hf:att:pa_angle-direction | hf:att:pa_applicable-gage | hf:att:pa_archive-data | hf:att:pa_assignable-cause-action | hf:att:pa_attribute-msa-4 | hf:att:pa_attribute-short-method | hf:att:pa_audit-trails | hf:att:pa_auto-generated-emails | hf:att:pa_automates-reporting | hf:att:pa_b-axis-indexing | hf:att:pa_batch-data-collection | hf:att:pa_battery | hf:att:pa_battery-life | hf:att:pa_bias-study | hf:att:pa_bluetooth-4-2 | hf:att:pa_bracket-kit | hf:att:pa_cable-length | hf:att:pa_cable-name | hf:att:pa_cable-type | hf:att:pa_classic-spc-views | hf:att:pa_cloud-environment | hf:att:pa_collection-scheduler | hf:att:pa_color | hf:att:pa_column-row-mapping | hf:att:pa_connection | hf:att:pa_connection-cable-required | hf:att:pa_connection-type | hf:att:pa_connection-unit-required | hf:att:pa_continuous-data-send | hf:att:pa_custom-calibration-cert | hf:att:pa_custom-calibration-proc | hf:att:pa_custom-report-templates | hf:att:pa_d2 | hf:att:pa_data-entry | hf:att:pa_data-input | hf:att:pa_data-output | hf:att:pa_data-processing-0 | hf:att:pa_data-processing-1 | hf:att:pa_data-processing-3 | hf:att:pa_data-reception-indication | hf:att:pa_data-send-button | hf:att:pa_data-send-switch | hf:att:pa_data-storage | hf:att:pa_datasheet | hf:att:pa_depth-of-field | hf:att:pa_display | hf:att:pa_edition | hf:att:pa_electronic-signatures | hf:att:pa_email-alerts | hf:att:pa_external-control | hf:att:pa_factory-quality-dashboard | hf:att:pa_filter | hf:att:pa_fit | hf:att:pa_fit-transmitter | hf:att:pa_footswitch-connection | hf:att:pa_form-vision-connectivity | hf:att:pa_free-mobile-apps | hf:att:pa_function | hf:att:pa_gage-capacity | hf:att:pa_gage-management | hf:att:pa_gage-rr | hf:att:pa_head-mounting | hf:att:pa_hoops-3d-view | hf:att:pa_import-ascii | hf:att:pa_import-gage-library | hf:att:pa_improves-work-efficiency | hf:att:pa_includes-sql-express | hf:att:pa_inputs | hf:att:pa_length | hf:att:pa_linearity-study | hf:att:pa_live-collection-dashboard | hf:att:pa_manager-views | hf:att:pa_mass | hf:att:pa_max-min-tir | hf:att:pa_maximum-extension-bar | hf:att:pa_measuring-tools | hf:att:pa_merge-copy-and-edit-data | hf:att:pa_model | hf:att:pa_mounting-options | hf:att:pa_network-connected | hf:att:pa_number-of-licenses | hf:att:pa_operating-temperature-range | hf:att:pa_optional-vcp-drivers | hf:att:pa_output | hf:att:pa_outside-dimensions | hf:att:pa_overtravel-break-load | hf:att:pa_pass-thru-port-input | hf:att:pa_pc-requirement | hf:att:pa_polling-from-pc | hf:att:pa_positional-repeatability | hf:att:pa_positions | hf:att:pa_power-supply | hf:att:pa_print-capacity | hf:att:pa_print-speed | hf:att:pa_printer-paper | hf:att:pa_printing-method | hf:att:pa_probe-mounting | hf:att:pa_probe-sockets | hf:att:pa_probe-status-indication | hf:att:pa_process-analyzer | hf:att:pa_process-manager | hf:att:pa_range-x-axis | hf:att:pa_range-y-axis | hf:att:pa_real-time-professional | hf:att:pa_real-time-standard | hf:att:pa_remarks | hf:att:pa_repeatability-of-position | hf:att:pa_report-scheduler | hf:att:pa_request-data | hf:att:pa_resolution | hf:att:pa_rs-232c-cable | hf:att:pa_rs232-output | hf:att:pa_scatter-chart | hf:att:pa_serial-rs232-input | hf:att:pa_signal | hf:att:pa_spc-cable | hf:att:pa_stability-study | hf:att:pa_suitable-interfaces | hf:att:pa_summary-analysis | hf:att:pa_supplies-5v | hf:att:pa_support-capability | hf:att:pa_supported-os | hf:att:pa_supports-mobile-devices | hf:att:pa_supports-u-wave | hf:att:pa_supports-usb-input-tool | hf:att:pa_supports-usb-itn | hf:att:pa_tagging-data | hf:att:pa_tech-support-included | hf:att:pa_test-for-normality | hf:att:pa_timed-data-collection | hf:att:pa_timed-data-send | hf:att:pa_timer-input | hf:att:pa_tolerance-judgement | hf:att:pa_track-gage-calibration | hf:att:pa_transmitter | hf:att:pa_type-1-study | hf:att:pa_u-wave-bluetooth | hf:att:pa_u-wave-r-required | hf:att:pa_u-wave-r-units | hf:att:pa_u-wave-t | hf:att:pa_u-wave-t-units | hf:att:pa_usb-cable | hf:att:pa_usb-drivers | hf:att:pa_usb-output | hf:att:pa_variable-crossed-anova | hf:att:pa_variable-crossed-range | hf:att:pa_variable-nested-anova | hf:att:pa_variable-nested-range | hf:att:pa_variable-range-method | hf:att:pa_workgroup-site-license | hf:att:pa_workpiece-max-load |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
543-562A | Inch/Metric | ID-H530E | 0-1.2in 0-30.4mm | 0.0015mm | .00002, .00005, .0001in 0.0005, 0.001mm | $862.10 | | inch-metric | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
543-564A | Inch/Metric | ID-H560E | 0-2.4in 0-60.9mm | 0.0025mm | .00002, .00005, .0001in 0.0005, 0.001mm | $1,026.75 | | inch-metric | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
543-561A | Metric | - | 0-30.4mm | 0.0015 | 0.0005, 0.001mm | $862.10 | | metric | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
543-563A | Metric | - | 0-60.9mm | 0.0025 | 0.0005, 0.001mm | $1,026.75 | | metric |
Optional Accessories
SKU | Description | Price | Buy | hf:att:pa_10-pin-digimatic-input | hf:att:pa_2d-view | hf:att:pa_a-axis-indexing | hf:att:pa_ac-adapter | hf:att:pa_academic-license | hf:att:pa_angle-direction | hf:att:pa_applicable-gage | hf:att:pa_archive-data | hf:att:pa_assignable-cause-action | hf:att:pa_attribute-msa-4 | hf:att:pa_attribute-short-method | hf:att:pa_audit-trails | hf:att:pa_auto-generated-emails | hf:att:pa_automates-reporting | hf:att:pa_b-axis-indexing | hf:att:pa_batch-data-collection | hf:att:pa_battery | hf:att:pa_battery-life | hf:att:pa_bias-study | hf:att:pa_bluetooth-4-2 | hf:att:pa_bracket-kit | hf:att:pa_cable-length | hf:att:pa_cable-name | hf:att:pa_cable-type | hf:att:pa_classic-spc-views | hf:att:pa_cloud-environment | hf:att:pa_collection-scheduler | hf:att:pa_color | hf:att:pa_column-row-mapping | hf:att:pa_connection | hf:att:pa_connection-cable-required | hf:att:pa_connection-type | hf:att:pa_connection-unit-required | hf:att:pa_continuous-data-send | hf:att:pa_custom-calibration-cert | hf:att:pa_custom-calibration-proc | hf:att:pa_custom-report-templates | hf:att:pa_d2 | hf:att:pa_data-entry | hf:att:pa_data-input | hf:att:pa_data-output | hf:att:pa_data-processing-0 | hf:att:pa_data-processing-1 | hf:att:pa_data-processing-3 | hf:att:pa_data-reception-indication | hf:att:pa_data-send-button | hf:att:pa_data-send-switch | hf:att:pa_data-storage | hf:att:pa_datasheet | hf:att:pa_depth-of-field | hf:att:pa_display | hf:att:pa_edition | hf:att:pa_electronic-signatures | hf:att:pa_email-alerts | hf:att:pa_external-control | hf:att:pa_factory-quality-dashboard | hf:att:pa_filter | hf:att:pa_fit | hf:att:pa_fit-transmitter | hf:att:pa_footswitch-connection | hf:att:pa_form-vision-connectivity | hf:att:pa_free-mobile-apps | hf:att:pa_function | hf:att:pa_gage-capacity | hf:att:pa_gage-management | hf:att:pa_gage-rr | hf:att:pa_head-mounting | hf:att:pa_hoops-3d-view | hf:att:pa_import-ascii | hf:att:pa_import-gage-library | hf:att:pa_improves-work-efficiency | hf:att:pa_includes-sql-express | hf:att:pa_inputs | hf:att:pa_item-type | hf:att:pa_length | hf:att:pa_linearity-study | hf:att:pa_live-collection-dashboard | hf:att:pa_manager-views | hf:att:pa_mass | hf:att:pa_max-min-tir | hf:att:pa_maximum-extension-bar | hf:att:pa_measuring-tools | hf:att:pa_merge-copy-and-edit-data | hf:att:pa_model | hf:att:pa_mounting-options | hf:att:pa_network-connected | hf:att:pa_number-of-licenses | hf:att:pa_operating-temperature-range | hf:att:pa_optional-vcp-drivers | hf:att:pa_output | hf:att:pa_outside-dimensions | hf:att:pa_overtravel-break-load | hf:att:pa_pass-thru-port-input | hf:att:pa_pc-requirement | hf:att:pa_polling-from-pc | hf:att:pa_positional-repeatability | hf:att:pa_positions | hf:att:pa_power-supply | hf:att:pa_print-capacity | hf:att:pa_print-speed | hf:att:pa_printer-paper | hf:att:pa_printing-method | hf:att:pa_probe-mounting | hf:att:pa_probe-sockets | hf:att:pa_probe-status-indication | hf:att:pa_process-analyzer | hf:att:pa_process-manager | hf:att:pa_range-x-axis | hf:att:pa_range-y-axis | hf:att:pa_real-time-professional | hf:att:pa_real-time-standard | hf:att:pa_remarks | hf:att:pa_repeatability-of-position | hf:att:pa_report-scheduler | hf:att:pa_request-data | hf:att:pa_resolution | hf:att:pa_rs-232c-cable | hf:att:pa_rs232-output | hf:att:pa_scatter-chart | hf:att:pa_serial-rs232-input | hf:att:pa_signal | hf:att:pa_spc-cable | hf:att:pa_stability-study | hf:att:pa_suitable-interfaces | hf:att:pa_summary-analysis | hf:att:pa_supplies-5v | hf:att:pa_support-capability | hf:att:pa_supported-os | hf:att:pa_supports-mobile-devices | hf:att:pa_supports-u-wave | hf:att:pa_supports-usb-input-tool | hf:att:pa_supports-usb-itn | hf:att:pa_tagging-data | hf:att:pa_tech-support-included | hf:att:pa_test-for-normality | hf:att:pa_timed-data-collection | hf:att:pa_timed-data-send | hf:att:pa_timer-input | hf:att:pa_tolerance-judgement | hf:att:pa_track-gage-calibration | hf:att:pa_transmitter | hf:att:pa_type-1-study | hf:att:pa_u-wave-bluetooth | hf:att:pa_u-wave-r-required | hf:att:pa_u-wave-r-units | hf:att:pa_u-wave-t | hf:att:pa_u-wave-t-units | hf:att:pa_usb-cable | hf:att:pa_usb-drivers | hf:att:pa_usb-output | hf:att:pa_variable-crossed-anova | hf:att:pa_variable-crossed-range | hf:att:pa_variable-nested-anova | hf:att:pa_variable-nested-range | hf:att:pa_variable-range-method | hf:att:pa_workgroup-site-license | hf:att:pa_workpiece-max-load |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
21EAA131 | RS232 CONNECTION CABLE (2M) | $195.00 | | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
21EZA099 | REMOTE CONTROLLER FOR ID-H | $94.80 | | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
21EZA101 | LIFTING KNOB (ID-H) | $33.05 | | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
21JZA295 | Spindle lifting cable (stroke: .4” / 10mm) | $46.15 | |
Features
This new-generation digital indicator offers the excellent accuracy and functionality expected from this class of indicator. Take advantage of its high accuracy backed up by 0.5ìm / .00002″ resolution, remote control functionality via a handheld controller (or an RS-232C interface) and easy runout measurements with the well-established analog bar display.
The maximum, minimum, or runout value can be displayed during measurement.
GO/±NG judgment is performed by setting the upper and lower tolerances. If a judgment result is out of tolerance, the display backlighting changes from green to red, so tolerance judgment can be made at a glance.
With SPC data output.
With RS-232C input/output
Technical Data
Accuracy: Refer to the list of specifications.
Resolution: 0.0005mm/0.001mm or .00002”/.00005”/.0001”/0.0005mm/0.001mm
Display: LCD
Length standard: Linear encoder
Max. Response speed: 1000mm/s
Measuring force: 2.0N/2.5N* or less (*60mm range models)
Power supply: 6V DC (via AC adaptor)
Function
Origin-set/Preset, Zeroset, GO/±NG judgment, Max/Min value hold, Runout measurement, Resolution switching, Counting
direction switching, Power ON/OFF, Data output, inch/mm conversion (on inch/metric models only)
Alarm: Low voltage, Counting value composition error, Over-flow error, Tolerance limit setting error
Standard Accessories
06AEG180JA: AC Adapter 120v
137693: Lifting Lever
Optional Accessories
936937: SPC cable (40” / 1m)
965014: SPC cable (80” / 2m)
21EAA131: RS-232C cable (80” / 2m)
21EZA099: Remote controller
540774: Spindle lifting cable (stroke: .4” / 10mm)
21EZA101: Spindle lifting knob
264-504-5A: Digimatic Min-processor DP-1VR